Izdelki za emf 5g zaščita (5)

EMF576D LVDS TCXO

EMF576D LVDS TCXO

LVDS output TCXO in 6 pad, 7.0 x 5.0mm SMD package. Frequency range 12MHz to 800MHz. Stability from ±1ppm -30°~+75°C. LVDS 'F' Group characteristics. RoHS Compliant. TCXO with LVDS output, 6 pad, 7 x 5mm SMD. Stability from ±1ppm -30°~+75°C. Miniature 7 x 5 x 2.8mm ceramic SMD package Supply voltage 3.3 Volts Low cost, low jitter for general applications RoHS compliant 'F' Group characteristics. Frequency Range 38.880MHz to 432.0MHz. Product Series Code TCXO:EMF576D VCTCXO: VEMF576D Frequency Range:12.0MHz to 800.0MHz Output Waveform:LVDS Initial Calibration Tolerance:<±2.0ppm at +25°±2°C Standard Frequencies:(Partial list) 12.8, 16.0 19.44, 20.0, 25.0, 27.0, 30.0, 32.0 Frequency Stability (see table) vs. Ageing:±1.0 ppm max. first year vs. Voltage Change: ±0.3 ppm max. ±5% change Supply Voltage:+3.3 Volts Differential Output Voltage VOD:247mV min., 355mV typical; 454mV max., Output 1 - Output 2 Differential Output Error dVOD:-50mV min., 50mV max. Output Offset Voltage VOS:1.125V min., 1.200V typ., 1.375V max Offset Magnitude Error dVOS:0mV min., 3.0mV typ., 25mV max Rise and Fall Times:1.5ns typical Duty Cycle:50%±5% Start-up Time:5ms typical, 10ms max. Current Consumption:12MHz to 24MHz: <33mA max., 24MHz to 96MHz: <50mA max., 96MHz to 800MHz:<85mA max Output Load:50W from each load Drive Capability:100W between LVDS and Complementary LVDS Storage Temperature:-55° to +125°C Phase Jitter (RMS) (12kHz to 20MHz):0.4ps typ., 0.5ps max
Višinsko Nastavljiva Telefonska Kabina M1

Višinsko Nastavljiva Telefonska Kabina M1

Elektrisch höhenverstellbar Das elektrische Höhenverstellsystem ermöglicht Ihnen eine schnellere Installation des Pods. Verpackungsreduzierung Für kostengünstigen Transport und bequemen Zugang zum Aufzug. Schallschutz Schalldämmung 25 dB ± 5 dB. Hält Außenlärm fern und minimiert interne Geräusche. Farbe nach Wunsch Die Farbe des Innen- und Außenfilzes des Pods kann nach Wunsch angepasst werden. Belüftungssystem Das verstellbare Belüftungssystem sorgt für frische Luft und erfüllt Ihre Vorlieben. *30 Tage kostenlos testen*
Stropna požarna vrata EI 60 - požarna past

Stropna požarna vrata EI 60 - požarna past

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboard Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018EN 1634-1: +A1: 2018 Fire dampers EI 60 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.
Stropna požarna vrata 120 MN - požarna past

Stropna požarna vrata 120 MN - požarna past

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018 Fire dampers EI 120 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 120. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.
Stropna požarna vrata 60 MIN - požarna vrata

Stropna požarna vrata 60 MIN - požarna vrata

Frame made of aluminium profile bars connected by "Tox" connections - Intumescent gas, smoke and flame tight seal in case of fire - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards - Quick and easy installation The 60-minute ceiling fire dampers are designed for installation in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60. They provide effective protection against fire progression from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms. The safety catching arms ensure that the lid is intercepted every time the hatch is opened. The lid is easy to remove and replace.